Level MetersLevel Meters,Chongqing chuanyi High-energy sound level meter HS series : HS–AWI(0–60m) measurement MW series: MW(0–10m) measurement Sultan series: AWI(0–60m) measurement MPS1000 series PULSE RADAR MPS1200 Application:Measuring corrosive liquid in complex conditions Measurement range:0-35m Process of Connection:1-1/2’’NPT whorl or flange Temperature:-40℃~150℃ Pressure:-1.0~3 kgf/cm2 Accuracy:±1cm Frequency Range:6GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires 4-20 mA output calibration for range set. By HART protocol to communicate MPS1300 Application:Measuring liquid and solid in complex conditions Measurement range:0-70m Process of Connection:Flange Temperature:-40℃~350℃ Pressure:-1.0~40kgf/cm2 Accuracy:±1cm Frequency Range:6GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires 4-20 mA output calibration for range set. By HART protocol to communicate MPS1300 Application:Measuring liquid and solid in complex conditions Measurement range:0-70m Process of Connection:Flange Temperature:-40℃~150℃ Pressure:-1.0~2kgf/cm2 Accuracy:±1cm Frequency Range:6GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires 4-20 mA output calibration for range set. By HART protocol to communicate
MPS3000 series PULSE RADAR MPS3100 Application:Measuring corrosive liquid Measurement range:0-20m Process of Connection:1-1/2’’ NPT、G3 whorl or flange Temperature:-40℃~150℃ Pressure:-1.0~3 kgf/cm2 Accuracy:±3mm Frequency Range:26GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires MPS3200 Application:Slightly corrosive liquid Measurement range:0-35m Process of Connection: flange Temperature:-60℃~400℃ Pressure:-1.0~40kgf/cm2 Accuracy:±3mm Frequency Range:26GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires MPS3300 Application:Measuring corrosive liquid in complex conditions Measurement range:0-20m Process of Connection: flange Temperature:-40℃~150℃ Pressure:-1.0~16kgf/cm2 Accuracy:±3mm Frequency Range:26GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires MPS3600 Application:Lump, granular solid measurement Measurement range:0-35m Process of Connection: flange Temperature:-60℃~400℃ Pressure:40kgf/cm2(Universal joint type instrument for atmospheric pressure) Accuracy:±3mm Frequency Range:26GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires MPS3700 Application:Granular, powdery solid measurement Measurement range:0-70m Process of Connection: flange Temperature:-60℃~400℃ Pressure:40kgf/cm2(Universal joint type instrument for atmospheric pressure) Accuracy:±3mm Frequency Range:26GHz Signal Output:4~20 mA HART Power supply:24VDC 、2-20mA、HART、Two-wires 24VDC 、4-20mA、Four-wires 220VAC 、4-20mA、Four-wires Guided Microwave Radar Transmitter Category MGS2100、MGS4100 Application liquid Measurement range 0-20m Measuring Medium • the permittivity of liquid is equal or greater than 1.4
Cable type electrode φ6mm(cable type ) Process of connection 1½NPT or flange Temperature -190℃~150℃(Apply to MGS2000 type) -190℃~400℃(Apply to MGS4000 type) Pressure -1.0~40kgf/cm2 power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p Maximum current: 22.5mA Category MGS2200、MGS4200 Application Liquid, powder and solid particles Measurement range 0-4m Measuring Medium • the permittivity of everything is equal or greater than 1.4 and CST≤500cst For steam and foam has a strong inhibition, measurement is not affected Cable type electrode φ10mm、φ12mm、φ16mm(stick) Process of connection 1½NPT or flange Temperature -190℃~150℃(Apply to MGS2000 type) -190℃~400℃(Apply to MGS4000 type) Pressure -1.0~40kgf/cm2 power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p Maximum current: 22.5mA Category MGS2500、MGS4500 Application Liquid Measurement range 0-4m Measuring Medium • the permittivity of everything is equal or greater than 1.4 and CST≤500cst
Cable type electrode Coaxial rod electrode Process of connection 1½NPT or flange Temperature -190℃~150℃(Apply to MGS2000 type) -190℃~400℃(Apply to MGS4000 type) Pressure -1.0~40kgf/cm2 power supply Normal power supply: 18~36VDC, ripple voltage: 100mv.vp.p EXia power supply: 18~28VDC, ripple voltage::100mv.vp.p Maximum current: 22.5mA
LastFlow MetersNextLevel Meters |